Pittsburgh PLI Fire Alarm Inspection

What Pittsburgh PLI (Permits, Licenses & Inspections) actually reviews on a commercial fire alarm — submittal expectations, inspection-tag checks, common flags.

No-obligation · 60-second request
Request your inspection.
A NICET certified technician on every job. Tell us where to start.
Tyrian Lead Form
NICET certified · NFPA 72 · No spam

What Pittsburgh PLI reviews.

  • Inspection-tag presence and currency inside the panel cabinet.
  • Current §10.18 Record of Inspection in the building's compliance file.
  • Design-submittal compliance for new construction and major retrofit (NICET IV / PE stamp).
  • §14.4.4 quarterly battery-test documentation.
  • Coverage compliance against the approved drawings — §17 detection, §18 notification.
  • Elevator recall functionality on buildings with elevators.
  • Mass notification / voice evac where occupancy class requires it.

Common PLI flags.

Missing or stale inspection tags. §10.18 records that show annual-only with no quarterly entries. Coverage drift from approved drawings after tenant build-outs. Elevator recall not demonstrated. POTS-line monitoring on a sunsetting AT&T circuit.

Tyrian and PLI.

Tyrian maintains ongoing relationships with Pittsburgh PLI inspectors and re-introduces on each new building. Audit-grade §10.18 reports are formatted for PLI review. Pre-submittal conversations on engineered design where the project supports.

Pittsburgh PLI FAQs.

PLI expects NICET IV or PA-licensed PE stamp on engineered fire alarm design drawings.

PLI compliance walks vary; routine occupancy reviews, complaint-driven inspections, and permit-driven reviews all occur.

Current §10.18 Record of Inspection, §7.5 Record of Completion, inspection tags. The audit-grade binder.

Full Pittsburgh AHJ code guide at /code/pittsburgh-fire-alarm-code/.

Keep exploring

Related pages

Fire Alarm Resources →Guides, codes and answers for PA commercial fire alarm.
ADA Fire Alarm Visual Notification →ADA visual notification requirements for commercial fire alarm — strobe coverage in occupied…
AHJ vs. Fire Marshal →The Authority Having Jurisdiction (AHJ) vs. the fire marshal — what each term means, when…
NFPA 72 Audibility Survey →Audibility survey methodology under NFPA 72 §18.4 — measuring ambient SPL, calculating margin,…
Duct Smoke Detector Requirements →Where NFPA 72 §17.7.5 (alarm-side duct detection) intersects NFPA 90A (HVAC standard). Common…
Elevator Recall Fire Alarm →Where NFPA 72 §21.3 elevator recall meets ANSI A17.1 — how detectors in elevator lobbies and…
Voice Evac Message Priority →How NFPA 72 §24.4.2.3.3 governs voice evacuation message priority — which pre-recorded message…
Fire Alarm Code Violations in Pennsylvania →Got a fire alarm code violation letter from a PA AHJ? The four-step cure playbook: document,…