Skip to content
NICET certified / NFPA 72 / UL-Listed 24/7 Monitoring
Serving Six Pennsylvania Metros▪(724) 660-FIRE
(724) 660-FIRE
NICET CERTIFIED/NFPA 72/PA METROS

Fire alarm FAQ.

What buyers ask us first — NFPA 72, inspections, AHJ, takeovers, and how Tyrian works.

No-obligation · 60-second request
Request your inspection.
A NICET certified technician on every job. Tell us where to start.
Tyrian Lead Form
NICET certified · NFPA 72 · No spam

Frequently asked questions.

A NICET certified technician on every job. Manufacturer-trained on the panels we install and service — experienced enough to spot the deficiency the previous vendor signed off on. We don’t send the apprentice to look at it.

No. Tyrian is alarm-only, by design. Fire alarm is its own discipline — NFPA 72, NICET certifications, panel-by-panel expertise. If you need sprinkler ITM or extinguisher service, we’ll refer you to the contractor we’d hire ourselves.

Everything NFPA 72 Chapter 14 requires. Panel inspection (AC power, battery load test, trouble conditions, zone labeling, monitoring transmission test), all initiating devices (smoke detectors visual and sensitivity, heat detectors, duct detectors, manual pull stations), all notification appliances (horn/strobes, speakers, visual devices), wiring and connection inspection on accessible circuits, and a central station transmission test with confirmation reference number.

First call: a walk of your last inspection report and your current contract. We document what’s in scope, what’s missing, and what your AHJ needs by when. The takeover follows a documented playbook — site assessment, written findings, service-agreement execution, monitoring transfer, and password and documentation handover to your ownership.

We sell, install, and service Kidde, Ajax, Silent Knight, and Fire-Lite. We can also work on other brands. Tell us the manufacturer, model and work needed so we can confirm the scope and any access requirements.

Six Pennsylvania metros: Pittsburgh, Erie, Harrisburg, York, Lancaster, and Reading. Same technicians, same reporting standard, same AHJ discipline in every market. Future expansion into Ohio and West Virginia as capacity grows.

Key signs: the system pre-dates current NFPA 72 editions and lacks supervisory features, parts are out of production, the panel won’t accept current addressable devices, the communicator is still on a POTS line scheduled for sunset, or your AHJ has cited the system for non-compliance. We assess on-site and document findings before recommending replacement.

Visual and functional inspection of every initiating device, every notification appliance, the control panel, batteries, monitoring transmission, and wiring on accessible circuits. Sensitivity testing of smoke detectors per Chapter 14. Reported within 48 hours after the inspection is complete and the office has received the findings electronically with every finding photographed and cited to its NFPA 72 section.

We deliver a written deficiency list classified Critical / Major / Minor with NFPA 72 citations and repair recommendations. We can quote remediation, schedule the work, and re-test for AHJ sign-off. The goal is to give the AHJ the documentation they need on the first re-submittal.

Yes. For installation and design work, we coordinate with the local AHJ on submittal requirements, pull permits, and manage the inspection schedule through final sign-off.

Annual NFPA 72 inspection (and semi-annual where required), priority response to system trouble and supervisory signals, monitoring service, and a documented system-of-record that travels with the building. Open-system commitment is contractual — your passwords, programming, and documentation belong to you.

Service-agreement clients get priority response. Same-week scheduling for non-emergency service across the six-metro footprint; faster for active trouble or supervisory conditions on critical systems.

Didn't find your question?

Call us or request an inspection — we’ll get back to you with an answer.

Keep exploring

Related pages

About Tyrian Fire Systems →Pennsylvania commercial fire alarm contractor. NICET certified technicians. NFPA 72…
Commercial Fire Alarm Inspection Pennsylvania →Audit-grade NFPA 72 fire alarm inspection across Pennsylvania’s metros — Pittsburgh, Erie, Lancaster,…
Commercial Fire Alarm Installation Pennsylvania →Design-build commercial fire alarm installation + retrofit across Pennsylvania’s metros. NICET certified…
Commercial Fire Alarm Monitoring Pennsylvania →UL 827-listed central station monitoring with TMA Five Diamond designation. Cellular + IP…
Fire Alarm System Design Pennsylvania →NICET certified fire alarm system design for PA commercial new construction, TI, and…
Contact Tyrian Fire Systems →Contact Tyrian Fire Systems — commercial fire alarm contractor serving Pittsburgh, Erie,…
Tyrian Fire Systems — commercial fire alarm

Commercial fire alarm — six Pennsylvania metros. NFPA 72 inspection, installation, monitoring. Open systems. Your passwords, your panel, your documentation.

244 Pfeifer Rd, Harmony, PA 16037
NICET certifiedUL-Listed MonitoringNFPA 72 Compliant© Tyrian Fire Systems